      PRODUCT CENTER
      1500

      1500 series positioner is designed for integral pneumatic control valve, particularly suitable for angle seat valves and diaphragm valves.
      The product is easy to operate. It can easily be operated via the keypad.
      The positioner adjusts the valve position quickly and accurately through detecting the position sensor signal.

      • LED Display
      • One Key Start-up
      • IP67 Protection Class
      Technical specification
      Technical data
      Structure
      Dimensions
      Interface angle adjustment
      Electrical connectors
      Pneumatic connectors
      Signal flow diagram
      Schematic diagram
      • Feedback signal
        Actuator type
        Valve max stroke
        Air Flow rate
        Thread type
        Power off state for single-acting

        Without feedback signal(N

        4-20mA feedback signal(Y

        Single-acting(S

        Double-acting(D

        Linear 5-25 mm(S2

        Linear 25-50 mm(S3

        Rotary 90°(S4

        17 L/min(Q1

        58 L/min(Q2

        G1/4(T1

        M16 * 1(T2

        M22 * 1.5(T3

        M26 * 1.5(T4

        Fail-safe(S

        Fail-freeze(F

      In the air flow rate option, code Q1 is suggested to match the actuator of 40-100 mm internal gas chamber diameter, code Q2 is suggested to match the actuator of 125-160 mm internal gas chamber diameter. Code Q2 is only used for single-acting actuator, and only in Freeze state when power-off. The air flow rates for code Q1 and Q2 are under the condition of 0.6Mpa input pressure.
      In the valve max stroke option, AT actuator range for code S4 is AT50~AT125. For other actuator models, please consult our company. It is no need to select the thread type option for code S4.
      Power off state for single-acting option is Safe by default.

      Technical Data
      Material PC,SI,PA6-GF30
      Power Supply 24V DC ±10%
      Set-point Signal 4 – 20 mA
      Input resistance for set-point signal 120Ω

      Control medium

      Dust concentration

      Particle density

      Pressure condensation point

      Oil concentration

      neutral gases, air DIN ISO 8573-1

      Class 5 (<40μm particle size)

      Class 5 (<10mg/m3)

      Cass 3 (<-20°C)

      Class 5 (<25mg/m3)

      Ambient temperature

      0-70°C

      Pneumatic connection

      Plug-in hose connector G1/4(internal Φ6mm)

      Electrical connection

      M12 3-pins B-coded (cable ? 4-6mm)

      M12 4-pins D-coded (cable ? 4-6mm)

      Supply pressure

      3~7 bar, specific values depending on the actuator

      Air flow rate

      17 L/min(input pressure of 0.6Mpa)

      58 L/min(input pressure of 0.6Mpa, only single-acting)

      Stroke control range

      Linear 5-50mm

      Rotary 90°

      Installation

      As required, Preferably with actuator in upright position, Screw

      Protection class

      IP66

      Power consumption

      <5W


      The angle can be adjusted between the positioner and the valve. If need to adjust the interface angle, relaxing the hexagon screw in place A first. Then adjusting the angle clockwise or counter-clockwise in 360°range. After adjusting the angle, locking the angle by the hexagon screw.


      X2(Optional)
      Pin Description Signal type
      1

      Analogue signal output +

      4 – 20 mA

      3

      Analogue signal output GND

      GND

      4

      -

      null

      X3
      Pin Description Signal type
      1
      Power supply +
      +24 V
      2

      Power supply GND

      GND

      3

      Set signal input +

      4 – 20 mA

      4

      Set signal input GND

      GND


      P

      Air supply enter(built-in filter, filter size 5 μm)

      R

      Air exhaust

      C

      Check valve

      A1

      Pilot air outlet 1

      A2

      Pilot air outlet 2



      <code id="lyzvy"><nobr id="lyzvy"></nobr></code>

      1. <th id="lyzvy"><video id="lyzvy"><span id="lyzvy"></span></video></th>
        1. <center id="lyzvy"><em id="lyzvy"></em></center>